<< Back to case
Conditions or Reasons for Planning Application - CB/18/03011/LB
Conditions or Reasons:
1) The works shall begin not later than three years from the date of this consent.

Reason: To comply with Section 18 of the Planning (Listed Buildings and Conservation Areas) Act 1990 as amended by Section 51 of the Planning and Compulsory Purchase Act 2004.
2) Notwithstanding the details submitted with the application the extent of wall fabric removal and the provision and method of required structural support and all works of making good associated with the development hereby approved shall be confirmed to the Local Planning Authority, for written approval, by way of annotated drawn detail at an appropriate scale between 1:10 and 1:20 following investigative works of opening up, and the development shall thereafter be undertaken in strict accordance with the approved details.
Reason: To ensure that the development hereby approved is undertaken with due regard to, and in safeguarding of, the historic fabric and character of this listed building
(Section 16, NPPF)
3) Following the carrying out or completion of the building operations or alterations for which consent is hereby granted, all making good of the existing building shall be carried out in materials & finishes which closely match, like-for-like, those historic materials & finishing details used in the existing building or structure- to accord with usual conservation good practice & to the satisfaction of the Local Planning Authority. If there is any doubt regarding the approach to any proposed making good, or any alternative materials are proposed, a precise specification of the materials & finishes should be submitted to & agreed in writing by the Local Planning Authority.

Reason: To ensure that the special architectural & historic interest, character & appearance of the building is properly maintained, in accordance with standard conservation good practice.
(Section 16, NPPF).
4) This consent relates only to the details shown on the submitted plans, numbers 118-L1A, 118-S1, 118-P7.

Reason: To identify the approved plan/s and to avoid doubt.


Return to Search | Close WindowTop of Page