<< Back to case
Conditions or Reasons for Planning Application - CB/22/03802/DOC
Conditions or Reasons:
4) No development shall commence until a detailed surface water drainage scheme, to manage surface water run off from the development. The scheme to be submitted shall include: (1) Plans and calculations for surface water drainage arrangements (to manage up to and including for the 1in100 year event + a 40% allowance for climate change); (2) Results of site-specific infiltration testing to support the design of infiltration devices (carried out in accordance with BRE 365); (3) if discharging to a watercourse/sewer/drain, confirmation that the rate of discharge will not exceed QBAR for all events; (4) Confirmation of the management and maintenance arrangements for the surface water drainage system in its entirety.

The scheme shall subsequently be implemented and maintained as approved. Maintenance will ensure the system functions as designed for the lifetime of the development.

Reason: To ensure the approved system will function to a satisfactory minimum standard of operation and maintenance and prevent the increased risk of flooding both on and off site, in accordance with Section 14 of the NPPF and its supporting technical guidance, and Local Plan policies CC3 and CC5.


Return to Search | Close WindowTop of Page